HCZ.
Column level indicators
ELESA Original design
HCZ.  - Column level indicators
Technical information

Material

Transparent polyamide based (PA-T) technopolymer. Resistant to shocks, solvents, oils with additives, aliphatic and aromatic hydrocarbons, petrol, naphtha, phosphoric esters. Avoid contact with alcohol and detergents containing alcohol.

Screws and nuts

Zinc-plated steel.

Packing rings

NBR synthetic rubber.

Contrast screen

White lacquered aluminium. The housing, in the appropriate external rear slot, guarantees the best protection from direct contact with fluid, avoiding yellowing effect due to the prolonged action of the fluid at high temperatures.
It can be removed before installation to fit marks and words (for example MAX-MIN).

Protection frame

Glass-fibre reinforced polyamide (PA) technopolymer, black colour, matte finish. Resistant to solvents, oils, greases and other chemical agents. Supplied assembled, removable by a screwdriver.

Standard executions

- HCZ: without thermometer and without protection frame.
- HCZ/T: with thermometer, without protection frame.
- HCZ-P: without thermometer, with protection frame.
- HCZ/T-P: with thermometer and protection frame.

Assembly

- By means of the supplied set screws and nuts.
- By means of the supplied set screws, without nuts, by tapping the two holes in the reservoir walls, if they are thick enough.
To ensure the best sealing of the O-rings it is recommended to apply the maximum torque on the nuts as reported in the table and a roughness of the gasket application surface Ra = 3 µm.

Maximum continuous working temperature

90°C (with oil).

Special executions on request

- HCZ.127: with M10 screws and nuts.
- UV resistant transparent technopolymer indicators.

Features and performances

The body of the indicator, entirely in transparent material, is assembled using ultrasound welding to guarantee a perfect seal.
Maximum fluid level visibility even from side positions.
Level visibility and temperature reading magnified by lens effect.
All shocks are absorbed by the frame that transmits them directly onto the wall of the reservoir, since the indicator is suspended between the rubber packing rings.
The frame is equipped with a wide front opening and three slots on each side that, combined with the indicator made entirely of transparent material, guarantee maximum fluid level visibility even from side positions.

Technical data

In laboratory tests carried out with mineral oil type CB68 (according to ISO 3498) at 23°C for a limited period of time, the weld stood up as follows:
- HCZ.76 18 bar
- HCZ.127 18 bar
If you need to use the indicator with other oils or fluids and under different pressure and temperature conditions, please contact ELESA Technical Department. In any case we suggest to verify the suitability of the product under the actual working conditions.

HCZ.  - Column level indicators
Standard ElementsMain dimensionsMounting holesThermometer scaleC #Weight
CodeDescriptionfdABCLemrd '-0.2f'±0.2°C°F[Nm]g
11382HCZ.7676M1022152299401811.510.576--1290
11383HCZ.76/T76M1022152299401811.510.57620÷10068÷2101291
11385HCZ.127127M12221522150802311.512.5127--12120
11386HCZ.127/T127M12221522150802311.512.51270÷10032÷21012121
11392HCZ.76-P76M102217.527105401814.510.576--12101
11393HCZ.76/T-P76M102217.527105401814.510.57620÷10068÷21012102
11395HCZ.127-P127M122217.527156802314.512.5127--12138
11396HCZ.127/T-P127M122217.527156802314.512.51270÷10032÷21012139
# Maximum tightening torque.