HCY-E
HCY-E
Oil electrical level indicators
with MIN level electrical sensor, technopolymer
with MIN level electrical sensor, technopolymer

78711-R,20
78710-R,10
78712-R,50
orGN 300-30-B5-SW;60
GN 612-5-M12x1,5-A;40
DIN 172-B10,5-20-A;50
ISO 8675-M8x1-04-BT;10
Transparent polyamide based (PA-T) technopolymer. Highly resistant to shocks, solvents, oils with additives, aliphatic and aromatic hydrocarbons, petrol, naphtha, phosphoric esters.
Avoid contact with alcohol or detergents containing alcohol.
Nickel-plated brass with hexagon socket.
NBR synthetic rubber O-Ring.
Polyamide based (PA) technopolymer in red colour, with a built-in magnetic element to activate the electric contact when the oil level drops to the minimum set at 40mm over the screw axis (dimension l).
Watertight, black colour, with a built-in relay (reed).
For a correct assembly see Warnings.
Right side output including protection against water sprays (protection class IP 65 according to EN 60529 table-).
White lacquered aluminium. The housing, in the appropriate external rear slot, guarantees the best protection from direct contact with fluid.
It can be taken out before assembly to allow the insertion of level lines or words.
80°C (with oil).
In laboratory tests carried out with mineral oil type CB68 (according to ISO 3498) at 23°C for a limited period of time, the weld stood up to: 14 bar (HCY.76), 9 bar (HCY.127) and 8 bar (HCY.254).
For use with other fluids and under different pressure and temperature conditions, please contact ELESA Technical Department.
In any case we suggest to verify the suitability of the product under the actual working conditions.
Electrical features | MIN level sensor |
Tension feed | AC/DC |
Electric contacts | NO normally open NC normally closed |
Maximum applicable voltage | NC: 150 Vac, 150 Vdc NO: 230 Vac, 230 Vdc |
Maximum commutable opening capacity | NC: 1A NO: 2A |
Maximum commutable power | NC: 20 W / 20 V.A. NO: 40 W / 40 V.A. |
Cable gland | Pg 7 (for cables in sheath with Ø 6 or 7 mm) |
Conductors cross-section | Max. 1.5 mm2 |
Do not mount this indicator in proximity to magnetic fields. |