HCZ. Column level indicators with or without protection frame, technopolymer


  • SUPER_TEC
  • RoHS
  • PA-T
  • g9030

Description

Main specifications

Material

Transparent polyamide based (PA-T) technopolymer. Resistant to shocks, solvents, oils with additives, aliphatic and aromatic hydrocarbons, petrol, naphtha, phosphoric esters.
Avoid contact with alcohol and detergents containing alcohol.

Protection frame

Glass-fibre reinforced polyamide (PA) SUPER-technopolymer, black colour, matte finish. Supplied assembled, removable by a screwdriver.

Screws and nuts

Zinc-plated steel.

Packing rings

Step-shaped for the seal on the reservoir walls and NBR synthetic rubber O-ring screw underhead.
Suggested roughness of the packing ring application surface Ra = 3 µm.

Contrast screen

White lacquered aluminium. The housing, in the appropriate external rear slot, guarantees the best protection from direct contact with fluid.
It can be taken out from the inclined side, before assembly to allow the insertion of level lines or words.

Standard executions

  • HCZ: without thermometer and without protection frame.
  • HCZ/T: with thermometer incorporated, without protection frame.
  • HCZ-P: without thermometer, with protection frame.
  • HCZ/T-P: with thermometer incorporated and protection frame.

Maximum continuous working temperature

90°C (with oil).

General information

Features and performances

Ultrasound welding to guarantee a perfect seal.
Lens effect for a better visibility of the fluid level and temperature.
Special openings in the protection frame provide maximum fluid level visibility even from side positions.
All shocks are absorbed by the frame that transmits them directly onto the wall of the reservoir.

Technical data

In laboratory tests carried out with mineral oil type CB68 (according to ISO 3498) at 23°C for a limited period of time, the weld stood up to: 18 bar (HCZ.76 and HCZ.127 ) 12 bar (HCZ.254).
For use with other fluids and under different pressure and temperature conditions, please contact ELESA Technical Department.
In any case we suggest to verify the suitability of the product under the actual working conditions.

Special executions

Special executions on request

  • HCZ.127: with M10 screws and nuts.
  • UV resistant transparent technopolymer indicators.
Column level indicators with or without protection frame, technopolymer HCZ.
Column level indicators with or without protection frame, technopolymer HCZ.
HCZ.
Filter
Code Description f d A B C L e m r d'-0.2 f'±0.2 C#
[Nm]
Weight
11382 HCZ.76 76 M10 22 15 22 99 40 18 11.5 10.5 76 12 90
11385 HCZ.127 127 M12 22 15 22 150 80 23 11.5 12.5 127 12 120
11388 HCZ.254 254 M12 22 15 24 278 203 25 12.5 12.5 254 12 150
HCZ.
Filter
Code Description f d A B C L e m r d'-0.2 f'±0.2 Thermometer scale°C Thermometer scale°F C#
[Nm]
Weight
11383 HCZ.76/T 76 M10 22 15 22 99 40 18 11.5 10.5 76 20÷100 68÷210 12 91
11386 HCZ.127/T 127 M12 22 15 22 150 80 23 11.5 12.5 127 0÷100 32÷210 12 121
11389 HCZ.254/T 254 M12 22 15 24 278 203 25 12.5 12.5 254 0÷100 32÷210 12 170
HCZ.
Filter
Code Description f d A B C L e m r d'-0.2 f'±0.2 C#
[Nm]
Weight
11392 HCZ.76-P 76 M10 22 17.5 27 105 40 18 14.5 10.5 76 12 101
11395 HCZ.127-P 127 M12 22 17.5 27 156 80 23 14.5 12.5 127 12 138
11398 HCZ.254-P 254 M12 22 17.5 29 284 203 25 15.5 12.5 254 12 150
HCZ.
Filter
Code Description f d A B C L e m r d'-0.2 f'±0.2 Thermometer scale°C Thermometer scale°F C#
[Nm]
Weight
11393 HCZ.76/T-P 76 M10 22 17.5 27 105 40 18 14.5 10.5 76 20÷100 68÷210 12 102
11396 HCZ.127/T-P 127 M12 22 17.5 27 156 80 23 14.5 12.5 127 0÷100 32÷210 12 139
11399 HCZ.254/T-P 254 M12 22 17.5 29 284 203 25 15.5 12.5 254 0÷100 32÷210 12 150